Thus, it is important to test every wrist strap/ footwear in order to protect sensitive electronic components the maximum wrist strap resistance should not be more than 10 meg ohms and footwear resitance should not be more than 35 Mohms. In order to protect sensitive electronic components the maximum wrist strap resistance should not be more than 10 Meg ohms and footwear resistance should not be more than 35 meg ohms. On the other hand, the resistance should not be less than 0.8 m ohm as protection to the wearer from dangerous levels of voltage and current flow. The wrist strap and the footwear tester checks these parameters under actual operating conditions with the strap on the wrist or footwear to the foot. It clearly indicates whether or not the resistance of the wrist strap/ footwear system including the wearer is atleast 800 kilo ohms and not more than 10 meg ohms / 35 meg ohms respectively. | |
Specifications: Pass Range : Wrist strap 0.8 meg ohms to 10 meg ohm / Footwear 0.8 meg ohms to 35 meg ohm High Range Selection:By slide Switch - 10 mohms- Wrist Strap / 35 mohms- ESD Footwear / Heel & Toe strap Indications : Pass - GREEN LED / Fail (low) - RED LED / Fail (High) - RED LED Audible Alarm for Fail mode. Actuation : By gently pressing metal sensor plate. Accuracy : +- 10% Power : 9 V DC battery Low Battery : Orange- Warning less than 7 volts Dimensions : 125 x 75 x 29mm Weight : 150 grams ( without battery) Calibration : Recommended every 12 months Traceability : To National Standards Warranty : 12 month |
||